DataFID™ LD



 

  

Photovac Editor's Choice

Advanced Portable Flame Ionization Detection for LDAR Monitoring

  • Bluetooth® enabled for wireless communication to hand-held datalogging PDA’s
  • Unique 70 hour, low pressure hydrogen fuel cylinder
  • Long-life 15 hour battery
  • Meets and exceeds USEPA Method 21 (LDAR) requirements
  • Intrinsically safe

Leak Detection and Repair (LDAR)

US EPA Method 21 regulation for fugitive emissions requires reliable measurements in a variety of environmental conditions. The DataFID meets and exceeds the requirements for instrumentation as stated in 40CFR Part 60 Method 21 as well a NSPS Subpart V V measurements in fuel ethanol and biodiesel production facilities.

Advanced Wireless Technology

The DataFID represents the newest generation in flame ionization technology with integral Bluetooth wireless technology for fast data download to a portable datalogging PDA. Now, cumbersome add-on Bluetooth communication attachments can be eliminated with the DataFID’s wireless technology. The DataFID is compatible with LDAR software systems such as LeakDAS®, and flame restart can be initiated through the software system.

Designed for Field Use

The revolutionary metal hydride hydrogen fuel cylinder allows up to 70 hours of continuous use at very low pressure (80 psi) to maximize your up-time in the field. With this long-life hydrogen fuel system, multiple shifts can use the DataFID without returning for a refill. The metal hydride cylinder has a UN3468 identification number, so it can be shipped full of hydrogen by way of air cargo.

DataFID LD Version Includes:

  • Bluetooth wireless technology
  • Metal hydride hydrogen cylinder
  • AC Charger 110/220 VAC with universal plug
  • 10 inlet filters
  • Multi-tool
  • User manual

Note:
Intrinsically safe PDA, Probe and LDAR software are available separately.

Photovac DataFID Specifications: LD Model

  • EPA Standards: Meets and exceeds USEPA Method 21 regulations for fugitive emissions monitoring (LDAR) US EPA 40 CFR Part 60 Method 21 and NSPS Subpart V V measurements in fuel ethanol and biodiesel production facilities.
  • Detector: Flame ionization
  • Size: 13”L x 12”W x 3” D (33cm x 30.5cm x 7cm) without backpack
  • Weight: 11.0 pounds (5 kg).
  • Display: Large 2.8” (7.1 cm) diagonal active area. Backlight manually activated.
  • Keypad: Four menu keys
  • Connectivity: Wireless Bluetooth technology installed inside DataFID housing. Does not require external Bluetooth device.
  • LDAR software compatibility. Communicates wirelessly with LDAR software systems.
  • Hydrogen operating time: 70 hours
  • Hydrogen tank pressure: 80psi (2,068 mmHg)
  • Hydrogen cylinder shipping classification: Can be shipped full of hydrogen by way of air cargo (shipping documentation required). Re-light after Flame-out: Can be re-lit from LDAR software.
  • Battery Capacity: 15 hours
  • Response time: < 3 seconds
  • Operating concentration range: 0.1 ppm to 50,000 ppm Operating temperature range: 32°F (0°C) to 122°F (50°C) Operating humidity range: 0 to 100% (non-condensing)
  • Accuracy: +/- 10% of reading
  • Repeatability: +/- 2%
  • Alarm level: Preset by operator Alarm: Audible at 85 dB, visual red LED on instrument body
  • Calibration Standards: Methane, hexane or propane
  • Intrinsic Safety; Class 1, Division 1, Groups A,B,C & D
  • FCC: Class B digital device, pursuant to Subpart B, class B of Part 15 of the FCC rules

DataFID LD Version requires intrinsically safe PDA, enterprise LDAR software and probe (available separately)

Specifications are subject to change without notice.
A component of this device is licensed under U.S. Patent No. 7,369,945 B2

  DataFID Calibration Instructions.pdf

   Download DataFID-LD product brochure

Request DataFID Product Manual