Voyager Industries
|
Environmental (Assay #1) Forty VOCs, including those listed in U.S. EPA Methods 8240 and TO-14 Petrochemical/Refining (Assay #2) Methanol, ethanol, methyl t-butyl ether (MTBE), t-amyl methyl ether (TAME), benzene, toluene, ethyl benzene, m-xylene, o-xylene ABS Rubber (Assay #4) Acrylonitrile, styrene, 1,3-butadiene Pulp and Paper (Assay #5) Hydrogen sulfide, methyl mercaptan, ethyl mercaptan, methyl ethyl ketone (MEK), dimethyl sulfide (DMS), dimethyl disulfide (DMDS), alpha-pinene, methanol, acetone Surfactants and Sterilants (Assay #6) Ethylene oxide, propylene oxide Latex Polymers (Assay #7) Methyl acrylate, ethyl acrylate, isobutyl acrylate, nbutyl acrylate, methyl methacrylate, acrylic acid, vinyl acetate, ethylene, styrene |
Chemicals Various volatile organic compounds (VOCs), chlorinated solvents Pharmaceutical Methylene chloride, acetonitrile, chloroform, acetone, toluene, hexane, methyl ethyl ketone, isopropanol, xylene, methanol Agricultural Fumigants Phosphine, bromomethane, sulfuryl fluoride Indoor Air Quality Acetone, benzene, chloromethane, ethanol, n-hexane, m-xylene, p-xylene, 2-propanol, toluene, 1,1,1-trichloroethane Adhesives Toluene, acrylate esters, industrial solvents |
Specifications
Size
15.4“ (39 cm) long, 10.6“ (27 cm) wide, 5.9“ (15 cm) high
Weight
15 lb. (6.8 kg) with battery installed
Keypad
4 fixed function keys and 4 menu keys
Display
128 x 64 element graphical LCD with backlighting
Battery Capacity
NiCd replaceable packs, extended life battery to power Voyager™
for up to 8 hours depending on ambient and column temperature
Serial Output
RS-232, for connection to Windows™ based PC and communication
to SiteChart software
Detectors
Photoionization detector with quick-change electrodeless discharge
UV lamp, 10.6 eV (standard); Electron Capture Detector (optional)
Alarm Output
Internal audio - 85 decibels
Alarm LED
Operating Temperature Range
41°F to 105°F (5°C to 40°C)
Operating Humidity
0-100% Relative Humidity (non-condensing)
Operating Concentration Range
Low detection limits are dependent on compound monitored.
Typical low detection limits are 5 ppb to 50 ppb. Consult
your representative for further information.
Power
10-18 VDC, 115 or 240 VAC, adapter provided
Intrinsic Safety
Class I, Division 1, Groups A, B, C, & D
Zone 1 locations, Eex ib m llC T4, Demko No. 97D 121 971